  "basis": "Independent assumed adhesive thickness comparison; not manufacturer data or physical validation",
  "footprint_mm": [
    18,
    30,
    68,
    100
  ],
  "fixed": "Graphite .10mm, kxy800/kz5; adhesive k.2; Rc each .0001; exterior cover inner face z7; sources/exterior sinks unchanged",
  "cases": {
    "reference": {
      "label": "25 \u00b5m \u00b7 Stage 06",
      "adhesive_thickness_mm": 0.025,
      "footprint_mm": [
        18,
        30,
        68,
        100
      ]
    },
    "medium": {
      "label": "50 \u00b5m adhesive",
      "adhesive_thickness_mm": 0.05,
      "footprint_mm": [
        18,
        30,
        68,
        100
      ]
    },
    "thick": {
      "label": "100 \u00b5m adhesive",
      "adhesive_thickness_mm": 0.1,
      "footprint_mm": [
        18,
        30,
        68,
        100
      ]
    }
  },
  "diagnostic": "Reference geometry, capacities, all in-plane links and other paths; change only two adhesive half-thickness terms in vertical interface resistances to100\u00b5m equivalent."
}